Manufacturing / Quality

Quality

Non-GMP manufacturing, released against customer specification.

Standard release data

CoAEvery batch
HPLCEvery batch
¹H NMR · SDSOn request
GC / KF / residual solventsPer specification
Impurity profile / ROSOn request

Control points

1 · Project startRoute risks and critical controls reviewed before work starts
2 · Raw materialsSupplier qualification, incoming inspection
3 · In processIPC at critical steps (HPLC / GC / KF)
4 · ReleaseTested against the agreed specification; CoA issued
5 · Retention and traceabilityRetained samples, traceable batch records

When our material is your RSM

Change notificationChanges to route, site, solvents or key raw materials notified in writing before they are made
RSM justification dataRoute description, impurity origin and fate, spiking and purge data for your ICH Q11 RSM justification
Quality agreementTemplate in the qualification kit, or we work from yours
AuditsRemote or on-site audits accepted

Batch CoA example

ProductGlutarimide
CAS1121-89-7
Formula / MWC₅H₇NO₂ / 113.12
Batch██████
Batch quantity1,325 kg
Manufactured / testedNovember 2026
Retest period12 months
StorageDry, tightly closed, protected from light
TestSpecificationResult
AppearanceWhite crystalConforms
Purity (HPLC)≥ 99.0%99.89%
Single impurity (HPLC)≤ 0.5%0.10%
Water (KF)≤ 0.5%0.18%
Taken from the CoA of a November 2026 batch made at Jiangjin; batch number and signatures withheld. Tested and independently reviewed, released under the quality department stamp.

Original batch CoA

The original with batch number, signatures and stamp is in the supplier qualification kit, sent by email.

Request kit